DeVilbiss FAC125 Guida alla Risoluzione dei Problemi

Navigare online o scaricare Guida alla Risoluzione dei Problemi per Compressori d'aria DeVilbiss FAC125. DeVilbiss FAC125 Troubleshooting guide Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
MODEL NO.
FA125
FAC125
MGP-FA125-3 9/18/99
SAFETY GUIDELINES - DEFINITIONS
Information for preventing damage to
equipment.
This manual contains information
that is important for you to know
and understand. This information
relates to protecting YOUR
SAFETY and PREVENTING
EQUIPMENT PROBLEMS. To
help you recognize this informa-
tion, we use the symbols to the
right. Please read the manual and
pay attention to these sections.
URGENT SAFETY INFORMATION - A HAZARD
THAT WILL CAUSE SERIOUS INJURY OR LOSS
OF LIFE.
Information that you should pay
special attention to.
IMPORTANT SAFETY INFORMATION - A
HAZARD THAT MIGHT CAUSE SERIOUS
INJURY OR LOSS OF LIFE.
Call our Toll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service
Center for ordering repair parts and for warranty repairs.
When ordering repair parts from your local Authorized Service Center, always give the following information:
Model number of your compressor
Part number and description of the item you wish to purchase
OWNERS MANUAL FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
(For Home Use Only)
SAFETY GUIDELINES .......................................................... 1
WARRANTY ........................................................................ 2
WARNING CHART ........................................................... 3-4
GLOSSARY ......................................................................... 5
DUTY CYCLE ....................................................................... 5
STORAGE ............................................................................ 5
DESCRIPTION OF OPERATION ........................................... 6
INSTALLATION AND BREAK-IN
PROCEDURES ................................................................ 6-7
Location of Air Compressor ........................................ 6
Extension Cords .......................................................... 6
Voltage and Circuit Protection .................................... 6
Grounding Instructions ................................................ 7
Additional Regulators and Controls............................ 7
Break-In Procedures ................................................... 7
OPERATING PROCEDURES ................................................ 8
TROUBLESHOOTING GUIDE ......................................... 9-10
COMPRESSOR PARTS LIST ............................................ 11
TABLE OF CONTENTS
MODEL NO.
Horsepower
SCFM @ 40 psig
SCFM @ 90 psig
Cut-In
Cut-Out
Bore
Stroke
Voltage/Hertz/ Phase
Minimum Branch Circuit
Requirement
*Fuse Type
Amperage at Max. Load
Tank Size
SPECIFICATION CHART
*A circuit breaker is preferred. Use only a fuse or
circuit breaker that is the same rating as the branch
circuit the air compressor is operated on. If the air
compressor is connected to a circuit protected by
fuses, use quick acting fuses.
FA125
1
3.7
2.7
100 PSI
125 PSI
1 3/4"
1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon
FAC125
-----
3.7
2.7
100 PSI
125 PSI
1 3/4"
1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon
Vedere la pagina 0
1 2 3 4 5 6 ... 35 36

Sommario

Pagina 1 - OWNERS MANUAL FOR

MODEL NO.FA125FAC125MGP-FA125-3 9/18/99SAFETY GUIDELINES - DEFINITIONSInformation for preventing damage toequipment.This manual contains informati

Pagina 2 - LIMITED WARRANTY

10 - ENGTROUBLESHOOTING GUIDE (Continued)CORRECTIONCAUSEPossible defect in safety valve.Knocking NoiseCompressor is not supplyingenough air to operate

Pagina 3 - IMPORTANT SAFETY INSTRUCTIONS

11 - ENGPARTS LISTAIR HOSEREGULATORSAFETY VALVETANK PRESSUREGAUGEPRESSURESWITCHAIR HOSEOUTLETPRESSURE GAUGECOMPRESSORASSEMBLYAIR TANKDRAIN VALVE(Not

Pagina 4 - HOW TO PREVENT IT

MODEL NO.FA125FAC125OWNERS MANUAL FORPERMANENTLY LUBRICATED AIR COMPRESSOR(For Home Use Only)DeVilbiss Air Power Company • 213 Industrial Drive •

Pagina 5 - DUTY CYCLE

MODÈLE NOFA125FAC125Appeler notre numéro gratuit 1-800-888-2458, ext. 2, puis 1, pour obtenir l’adresse du centre de service autorisé le plusproche po

Pagina 6 - DESCRIPTION OF OPERATION

2 - FRConservez le reçu de caisse comme preuve d’achat devant servir à justifier les travaux requis sous garantie..Appliquez tous soins raisonnables à

Pagina 7 - GROUNDING INSTRUCTIONS

3 - FR RISQUED’ÉCLATEMENTRISQUE DE FEU OUD’EXPLOSIONPURGER LE RÉSERVOIR QUOTIDIENNEMENT OUAPRÈS CHAQUE UTILISATION. SI LE RÉSERVOIRACCUSE UNE FUITE,

Pagina 8 - OPERATING PROCEDURES

4 - FRRISQUE DE CHOCÉLECTRIQUERISQUE DE PROJECTIOND’OBJETSRISQUE PAR INHALATIONRISQUE CAUSÉ PAR LESPIÈCES MOBILESRISQUE DE BRÛLURESCTMCWPS — 5/1/97VOT

Pagina 9 - TROUBLESHOOTING GUIDE

5 - FRGLOSSAIREPCNM : (Pied cube normal par minute) Unité de mesure dudébit d’airPRESSION MANOMÉTRIQUE @ lb/po.2 : Pressionmanométrique @ ... livre/po

Pagina 10 - CORRECTION

6 - FRDESCRIPTION DU FONCTIONNEMENTPROCÉDÉS D'INSTALLATION ET DE RODAGEEmplacement du compresseur d’airVotre compresseur d’air vous est livré com

Pagina 11 - PARTS AVAILABLE FOR THIS UNIT

7 - FRPROCÉDÉS D'INSTALLATION ET DE RODAGEDIRECTIVES DE MISE À LA TERRESECOUSSES ÉLECTRIQUES À REDOUTER ! ENCAS DE COURT-CIRCUIT, UNE MISE À LA T

Pagina 12

2 - ENGLIMITED WARRANTYONE YEAR FROM DATE OF PURCHASEAll merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to

Pagina 13 - MANUEL DU PROPRIÉTAIRE

8 - FRPROCÉDÉ DE FONCTIONNEMENT1. Avant d’attacher tuyau flexible ou accessoire, vérifiez si lelevier OFF/AUTO est bien en position “OFF” et si le rob

Pagina 14 - GARANTIE LIMITÉE

9 - FRGUIDE DE DÉPANNAGEPENDANT LES TRAVAUX DE RÉPARATION, VOUS RISQUEZ D’EXPOSER LES SOURCES DE TENSION, LES PIÈCESMOBILES OU LES SOURCES D’AIR COMPR

Pagina 15 - PRÉVENTION

10 - FRCAUSEPROBLEME REMEDEGUIDE DE DÉPANNAGE (Suite)Fuite d’air depuis la soupapede sûreté.CliquetisLe compresseur ne fournit passuffisamment d’air p

Pagina 16

11 - FRLISTE DE PIÈCES DÉTACHÉESPIÈCES DISPONIBLES POUR CET APPAREILDESCRIPTION NUMÉRO DE PIÈCERÉGULATEUR ...

Pagina 17 - CYCLE DE SERVICE

MODÈLE NOFA125FAC125DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615MANUEL DU PROPRIÉTAIRECOMPRESSEUR D'AIR À L

Pagina 18 - DESCRIPTION DU FONCTIONNEMENT

MODELO NO.FA125FAC125Llame a nuestro número de teléfono gratis 1-800-888-2458, ext. 2, entonces 1, para obtener la dirección del centrode servicio aut

Pagina 19 - Modèles 120 volts

2 - SPConservar la factura o recibo original como prueba de compra para el trabajo de garantía.Dar cuidado razonable al equipo durante su operación y

Pagina 20 - PROCÉDÉ DE FONCTIONNEMENT

3 - SPCONTINÚA EN LA SIGUIENTE PÁGINA RIESGO DE EXPLOSIÓNRIESGO DE INCENDIOO EXPLOSIÓNDRENAR EL TANQUE DIARIAMENTE O DESPUÉSDE CADA USO. SI SE LE PRO

Pagina 21 - GUIDE DE DÉPANNAGE

4 - SPRIESGORIESGO DE CHOQUE ELÉC-TRICORIESGO DE OBJETOS PRO-PULSADOSRIESGO A LA RESPIRACIÓNRIESGO DEPIEZAS MOVIBLESRIESGO DE QUEMADURASQUE PUEDE SUCE

Pagina 22 - GUIDE DE DÉPANNAGE (Suite)

5 - SPGLOSARIOSCFM o CFM: Pies cúbicos estándar por minuto; una unidadde medida del aire producido.PSIG o PSI: Libras por pulgada cuadrada leídas en

Pagina 23 - LISTE DE PIÈCES DÉTACHÉES

3 - ENGCONTINUE NEXT PAGE RISK OF BURSTINGRISK OFEXPLOSION OR FIRERISK OFELECTRICAL SHOCKAIR TANKTHE FOLLOWING CONDITIONS COULD LEADTO A WEAKENING OF

Pagina 24 - MODÈLE N

6 - SPDESCRIPCIÓN DE LA OPERACIÓNdesee. Dependiendo del requerimiento de presión de cadaaccesorio en particular, la presión de salida deberá regulars

Pagina 25 - MANUAL DEL OPERADOR PARA

7 - SPINSTALACIÓN Y PROCEDIMIENTOS PARA ELASENTAMIENTO Modelos de 120 VoltiosALAMBREBLANCOTIERRAENCHUFEDE 15 AMPTOMACORRIENTEESPIGA PARATIERR

Pagina 26 - GARANTÍA LIMITADA

8 - SPPROCEDIMIENTOS PARA OPERARAl Terminar:6. Mover la palanquita de “OFF/AUTO” a la posición de“OFF”.7. Girar el regulador contra el sentido del rel

Pagina 27 - QUE PUEDE SUCEDER

9 - SPGUÍA PARA DIAGNÓSTICO DE PROBLEMASAL HACER EL MANTENIMIENTO PUEDEN QUEDAR EXPUESTAS LAS FUENTES DE VOLTAJE, PARTES MOVIBLES OFUENTES DE AIRE COM

Pagina 28 - CTMCWPS — 5/1/97

10 - SPCAUSAPROBLEMA SOLUCIÓNGUÍA PARA DIAGNÓSTICO DE PROBLEMASFuga de aire por la válvula deseguridad.Sonido de golpes.El compresor no proveesuficien

Pagina 29 - CICLO DE TRABAJO

11 - SPLISTA DE REPUESTOSREPUESTOS DISPONIBLES PARA ESTA UNIDADDESCRIPCIÓN NÚMERO DE PARTEREGULADOR ...

Pagina 30 - ASENTAMIENTO

MODELO NO.FA125FAC125DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615MANUAL DEL OPERADOR PARACOMPRESOR DE AIRE DE LU

Pagina 31

4 - ENGHAZARDRISK OFELECTRICAL SHOCKRISK FROMFLYING OBJECTSRISK TO BREATHINGRISK FROMMOVING PARTSRISK OF BURNSWHAT CAN HAPPENREPAIRS ATTEMPTED BY UNQU

Pagina 32 - PROCEDIMIENTOS PARA OPERAR

5 - ENGGLOSSARY which the motor automatically re-starts is called "cut-inpressure."CUT-OUT PRESSURE: When you turn on your air com-pressor

Pagina 33 - PROBLEMA CAUSA SOLUCIÓN

6 - ENGDESCRIPTION OF OPERATIONAir Compressor Pump: To compress air, the pistonmoves up and down in the cylinder. On the downstroke, airis drawn in t

Pagina 34 - CAUSAPROBLEMA SOLUCIÓN

7 - ENGBreak-in ProceduresINSTALLATION AND BREAK-INPROCEDURESGROUNDING INSTRUCTIONSAdditional Regulators andControlsSince the air tank pressure is

Pagina 35 - LISTA DE REPUESTOS

8 - ENGOPERATING PROCEDURES1. Before attaching air hose or accessories, make surethe OFF/AUTO lever is set to “OFF” and the airregulator or shut-off

Pagina 36 - MODELO NO

9 - ENGDefective air tank.CORRECTIONExcessive tank pressure - safetyvalve pops off.Pressure switch does not shut off mo-tor when compressor reaches “c

Commenti su questo manuale