Page 4 SB-2-777-F
Chart 1 – FLG4 HVLP and Conventional Models, Siphon / Pressure
Spray Gun
Model Number
Application Type
Number
on
Air Cap
Air Cap Kit
(Ref. No. 1)
Fluid Tip
(Ref. No. 2)
Fluid Tip Size
Supplied With Gun
FLG-HVP-315 Pressure – HVLP 3 FLG4-1-3-K FLG-332-15K 1.5 mm
FLG-HVS-322 Siphon/Pressure – HVLP 3 FLG4-1-3-K FLG-332-22K 2.2 mm
FLG-CNS-115 Siphon / Pressure – Conventional 1 FLG4-1-1-K FLG-332-15K 1.5 mm
Chart 2 – Fluid Tips
Fluid Tip & Seal
(Ref. No. 2)
Part No.
Fluid Tip
Size
(in.)
Fluid Tip
Size
(mm)
Applications
FLG-332-13K 0.051 1.3 Stains, lacquers, basecoats, clears.
FLG-332-15K 0.059 1.5 General purpose, light to medium viscosity material.
FLG-332-22K 0.086 2.2 Medium viscosity materials.
Chart 3 – HVLP Air Flows (#3 Cap)
Inlet Pressure
(PSI)
Air Flow
(SCFM)
Cap Presure
(PSI)
15 10 6
19 11.5 8
23 13.5 10
FLG4 SIPHON / PRESSURE FEED SPRAY GUNS AND DeKUPS
®